45.0Hz-500Hz Ac Power Supply For Car Stereo Electrical Power Meters
TH7105 45.0Hz-500Hz AC Power Supply Power Electronic Tester
-
Programmable and Remote Control: Advanced DC Power Supplies offer programmable features and remote control capabilities. They can be interfaced with computers or control systems through various communication protocols such as USB, Ethernet, or GPIB (General Purpose Interface Bus). This allows for automated testing, remote operation, and integration into larger test setups or manufacturing systems. Programmable DC Power Supplies often provide software interfaces or programming languages for creating custom test sequences and automating complex power profiles.
-
Features
■ 24-bit color 4.3-inch 480 × 272 color LCD screen, Chinese and English interfaces
■ Linear output design
■ Flexible and convenient operation: numeric keypad, coarse and fine adjustment knob
■ Manual / program control mode output function, timing output function, dimming mode output function, surge and notch function
■ Front panel output function
■ Boot hold function
■ Store setting parameters and test results
■ Support USB to upgrade the instrument firmware
■ Multiple protection modes: set the current protection (HI-A)
Overvoltage Protection (OVP), Low Voltage Protection (LVP)
Overcurrent protection (OCP), over power protection (OPP)
Over temperature protection (OTP)
■ Two-gear temperature to control fan speed
■ Remote input and output functions:
Remote input: input control of 7 groups of memory
Remote output: PASS, FAIL, PROCESSING, internal output switch
■ Memory capacity:
Manual: 50 groups
Program control: 50 groups, 9 steps / group
Application
■ Motors and transformers
■ Electronic production design
■ Lighting
■ Aerospace military
■ Network communication
■ Audio and video equipment
■ Monitoring equipment
■ Power specifications simulation of different countries
■ Electromagnetic compatibility equipment
Specifications
Model | TH7105 | TH7110 | TH7120 | |
Output Parameters | ||||
Rated Power | 500W | 1000W | 2000W | |
Output Voltage | 0-300V | |||
Output Frequency | 45.0Hz-500Hz | |||
Maximum Current | 0-150V | 4.2A | 8.4A | 16.8A |
(RMS) | 0-300V | 2.1A | 4.2A | 8.4A |
MaximumCurrent | 0-150V | 16.8A | 33.6A | 67.2A |
(Peak) | 0-300V | 8.4A | 16.8A | 33.6A |
Total Harmonic Distortion (THD | at 45.0 -500Hz, ≤ 0.5% (resistive load) | |||
Common Parameters |
Phase | 1Ø/2W | ||
Crest Factor | ≥4 | |||
Linearity Adjustment Rate | 0.1%±10% | |||
Load Regulation | 0.5%(resistive load) | |||
Response Time | <100uS | |||
Setting Parameters | ||||
Voltage | -300V | |||
Resolution/Accuracy | 0.1V/±0.5%+2 digits | |||
Frequency | 45.0Hz -500Hz | |||
Resolution/Accuracy | <100Hz: 0.1Hz ; ≥100Hz: 1Hz/±0.02% | |||
Initial / Final Phase Angle | - 359° | |||
Resolution/Accuracy | 1°/±1°(45 - 65Hz) | |||
Measurement Parameters | ||||
Voltage | - 300V | |||
Resolution/Accuracy | 0.1V/±0.5%+2 digits | |||
Frequency | 45.0Hz -500Hz | |||
Resolution/Accuracy | <100Hz: 0.1Hz ; ≥100Hz: 1Hz/±0.1Hz | |||
Current | 0-150V | 0.000 - 4.200A | 0.000 - 8.400A | 0.000 - 16.800A |
0-300V | 0.000 - 2.100A | 0.000 - 4.200A | 0.000 - 8.400A | |
Resolution | 0.001A | |||
Accuracy | ±0.5%+5 digits | |||
Peak Current | 0-150V | 0.00 - 16.80A | 0.00 - 33.60A | 0.00 - 67.20A |
0-300V | 0.00 - 8.40A | 0.00 - 16.80A | 0.00 - 33.60A | |
Resolution | 0.01A | |||
Accuracy | ±5%+2 digits | |||
Power | Range | 0-500W | 0- 1000W | 0-2000W |
Resolution | 0.1W | 0.1W(0-1000W); 1W(1000-2000W) |
||
Accuracy | ±0.6%+5 digits | |||
Power Factor | 0.001-1.000 | |||
Resolution/Accuracy | 0.001/±2%+2 digits |