Send Message
Home > products > Micro Ohm Tester > TH9010 Separate Channel TFT-LCD Display Hipot Tester

TH9010 Separate Channel TFT-LCD Display Hipot Tester

Category:
Micro Ohm Tester
Specifications
Highlight:

10hz-15mhz portable impedance analyzers

,

10hz-15mhz impedance network analyzers

,

10hz-15mhz handheld impedance analyzers

Introduction

TH9010 Separate Channel TFT-LCD Display Hipot Tester

Features

■ 7-inch 800×480 dot-matrix, TFT-LCD display

■ Chinese and English operation interface and concise interfacet operation design

■ 8-channel withstand voltage parallel output and test efficiency increased eight times

■ Parallel 8-channels and each channel is non-interfering

■ Each channel can be extended by a four-channel scanner

■ Support 4 four-channel scanner at most and one instrument can be extended to 128 channels

■ Four-channel scanner supports contact check function

■ Single output power: AC:5kV/10mA; DC:6kV/5mA

■ Insulation resistance test voltage: 0.10kV -1.00kV

■ Enhanced security: electric shock protection

■ Rapid discharge and arc detection function

■ Arbitrarily set voltage rising time and test time in 999.9 seconds;freely set waiting time for insulation resistance

■ Key-Lock Function

■ Display the PASS/FAIL result of each channel independently and the total result simultaneously

■ Store 100 test files and each file can hold at most 20 testing steps

 

Application

■ Automated test system

■ Household appliances

■ Transformers, motors

■ Electrical equipment

■ Lighting industry

■ New energy vehicles

■ Electronic components

■ Medical equipment

 

Specifications

Model TH9010 TH9010A
Number of Units separate channel separate channel
Withstanding Voltage Test  
Output Voltage AC 0.10kV — 5.00kV ±2%
DC 0.10kV — 6.00kV ±2%
Current TestRange AC 0mA — 10.00mA ±(2% readings + 5 digits)
DC 0uA — 5.00mA ±(2% readings + 5 digits)
Rapid Discharge Function Discharge after test ends (DCW)
Insulation Resistance Test  
Output Voltage 0.10kV — 1.00kV ±2%
Resistance Test Range 0.1MΩ — 10.0GΩ
Resistance Test Accuracy

0.10MΩ — 999MΩ ±10% reading+5digits

1.00GΩ — 10.0GΩ ±20% reading+5digits

Discharge Function Discharge after test ends
Arc Detection  
Test Range Corresponding Current 1mA — 20mA
General Specification  
Voltage Rising Time 0.1s — 999.9s
Test time Setting (AC/DC) 0.2s — 999.9s
Voltage Fall Time 0.1s — 999.9s
Waiting Time (IR) 0.2s — 999.9s
Time Accuracy ±(1%+0.1s)
Memory Store 100 test files and each file can hold at most 20 testing steps
Interface  
Standard HANDLER, RS232, USB DRV, USB HOST

 

Accessary

Standard
Accessories name Model  
RS232 connection cable (with TH10101) (two holes at both ends, 2 and 3 feet cross) (2H/DB-9F 2/L 140 TH26034 TH9010 Separate Channel TFT-LCD Display Hipot Tester
TH9010 series high voltage test cable (without clip) TH90016 TH9010 Separate Channel TFT-LCD Display Hipot Tester
TH9010 series high voltage test cable (with clip) TH90015 TH9010 Separate Channel TFT-LCD Display Hipot Tester
Send RFQ
Stock:
MOQ: