Tonghui TH2516B DC Resistance Meter - 4.3'' Touch LCD Screen & 1u Minimum Resolution
-
Measurement Accuracy and Resolution: DC Resistance Meters are designed to provide accurate and precise resistance measurements. They employ high-quality measurement circuitry and calibration techniques to ensure reliable and repeatable results. The meters often offer various measurement ranges and selectable resolution settings to accommodate a wide range of resistance values and measurement requirements.
Features
Maximum resistance accuracy: 0.05%
Temperature accuracy: 0.2℃
Minimum resolution: 1u
Low-resistance test mode can effectively protect DUT
Multiple measurement combinations of R, LPR, T
24 bits, 4.3-inch and 4-wire touch LCD screen
LCD resolution: 480×272
Temperature compensation(TC)
Temperature conversion(t)
Maximum sample rate: 50samps/sec
Offset voltage compensation (OVC)
Customer self-correction(0 ADJ)
Simultaneously output compare results of 3 bins(OVER, PASS and BEEP)
Statistics function: CpK, Cp
30 groups of parameter files can be saved and loaded
Screen information can be stored on U-disk
Data save function brings convenience for saving measurement result
Automatically update operation software through USB HOST
Operation languages: Chinese and English
Flexible and convenient file operation system
Handler interface realizes on-line operation
Achieve data communication with PC and remote control through interfaces such as RS232, USB HOST, USB Device
Brief Introduction
On the basis of rich experience in impedance test and wide market research, now Tonghui launches the new DC impedance measurement instrument with touch and LCD screen ---TH2516 DC Resistance meter. TH2516, with elegant appearance, easy operation and excellent performance, is comparable to the most advanced products in the market.
TH2516 adopts 32 bits CPU and high density SMD technology.24 bits, 4.3-inch and touch LCD screen brings ease for your eyes and convenience to your operation. The maximum 0.05% accuracy and minimum 1 resolution shore up its leading role in testing relay contact resistance, interconnecting resistance, conductor resistance, PCB resistance and weldinghole resistance.
Temperature compensation and conversion functions make your tests be free from the effect of the environment temperature. The offset voltage compensation has effectively eliminated the electromotive force of the DUT and its contact potential difference. For the contact influence of the thermoelectricity on DUT, its elimination is achieved.
Automation on production lines can be greatly improved by the realization of ultra-high test speed and the signal output of 3 compare results through HANDLER interface.
Specifications
Model | TH2516B | |||
Display | ||||
Display | 24-bit, 480 X 272 and touch TFT LCD screen | |||
Reading digits | 4 digits | |||
Resistance measurement | ||||
Measurement range | 1 20k | |||
Resistance range | Current | Resolution | *Accuracy Rd%+digits | |
20 m | 1A | 1 | 0.100+3 | |
200m | 100mA | 10 | 0.1+2 | |
2 | 100 | |||
20 | 10mA | 1m | ||
200 | 1mA | 10m | ||
2k | 100A | 100m | ||
20k | 1 | |||
200k | ------ | |||
2M | ------ | |||
Measurement function | ||||
Resistance measurement time | FAST:10ms; MED:25ms; SLOW1:115ms; SLOW2:455ms | |||
Above data is correct when DISPLAY is OFF; when DISPLAY is ON, 20ms should be added. |
||||
Temperature measurement time | ------ | |||
Test terminal | 4-terminal | |||
Average setup | 1--255 | |||
Zero clearing | √ | |||
Range switch | Auto, Manual | |||
Trigger mode | Internal, Manual, External, BUS | |||
Power frequency selection | √ (avoid the interface of the power noise) | |||
Setting data storage | 30 groups | |||
Low voltage measurement | Open voltage40mV | |||
Effective range: 2, 20, 200, 2k | ||||
Thermal electromotive force elimination |
------ | |||