automated hipot tester
,hipot tester 6kv
,hipot tester dc
TH9010 Hipot Tester with 8-Channel Parallel Output for Automated Test System
-
Compliance with Standards: Hipot Testers are designed to comply with industry standards and regulations for electrical safety testing. They are built to meet specific safety standards such as IEC 61010 or UL 120k, ensuring that the testers themselves are safe to use and provide reliable results.
Features
7-inch 800×480 dot-matrix, TFT-LCD display
Chinese and English operation interface and concise interfacet operation design
8-channel withstand voltage parallel output and test efficiency increased eight times
Parallel 8-channels and each channel is non-interfering
Each channel can be extended by a four-channel scanner
Support 4 four-channel scanner at most and one instrument can be extended to 128 channels
Four-channel scanner supports contact check function
Single output power: AC:5kV/10mA; DC:6kV/5mA
Insulation resistance test voltage: 0.10kV -1.00kV
Enhanced security: electric shock protection
Rapid discharge and arc detection function
Arbitrarily set voltage rising time and test time in 999.9 seconds;freely set waiting time for insulation resistance
Key-Lock Function
Display the PASS/FAIL result of each channel independently and the total result simultaneously
Store 100 test files and each file can hold at most 20 testing steps
Application
Automated test system
Household appliances
Transformers, motors
Electrical equipment
Lighting industry
New energy vehicles
Electronic components
Medical equipment
Specifications
Model | TH9010 | TH9010A | |
Number of Units | separate channel | separate channel | |
Withstanding Voltage Test | |||
Output Voltage | AC | 0.10kV5.00kV2% | |
DC | 0.10kV6.00kV2% | ||
Current TestRange | AC | 0mA10.00mA(2% readings + 5 digits) | |
DC | 0uA5.00mA(2% readings + 5 digits) | ||
Rapid Discharge Function | Discharge after test ends (DCW) | ||
Insulation Resistance Test | |||
Output Voltage | 0.10kV1.00kV2% | ||
Resistance Test Range | 0.1M10.0G | ||
Resistance Test Accuracy |
0.10M999M ±10% reading+5digits 1.00G10.0G ±20% reading+5digits |
||
Discharge Function | Discharge after test ends | ||
Arc Detection | |||
Test Range | Corresponding Current | 1mA20mA | |
General Specification | |||
Voltage Rising Time | 0.1s999.9s | ||
Test time Setting (AC/DC) | 0.2s999.9s | ||
Voltage Fall Time | 0.1s999.9s | ||
Waiting Time (IR) | 0.2s999.9s | ||
Time Accuracy | ±(1%+0.1s) | ||
Memory | Store 100 test files and each file can hold at most 20 testing steps | ||
Interface | |||
Standard | HANDLER, RS232, USB DRV, USB HOST |
Accessary
Standard | ||||||
Accessories name | Model | |||||
RS232 connection cable (with TH10101) (two holes at both ends, 2 and 3 feet cross) (2H/DB-9F 2/L 140 | TH26034 | |||||
TH9010 series high voltage test cable (without clip) | TH90016 | |||||
TH9010 series high voltage test cable (with clip) | TH90015 |
Optional | ||||||
Accessories name | Model |