logo
Send Message
Home > products > Hipot Tester > Hipot And Ground Bond Tester Continuity 1.00-5.00A 0-600m

Hipot And Ground Bond Tester Continuity 1.00-5.00A 0-600m

Category:
Hipot Tester
Specifications
Features:
Data Import, Data Export, Data Analysis, Data Visualization
Data Automation:
Scheduling, Automated Reports, Automated Tasks
Data Backup:
Automatic, Manual, Cloud Backup
Data Formats:
Table, Graph, Chart, Map
Data Integration:
API, Webhooks, Database Connectors
Data Security:
Encryption, Password Protection, Access Control
Data Sharing:
Email, Social Media, File Transfer
Data Sources:
Excel, CSV, JSON, XML
Data Storage:
Cloud, Local, Remote
Language:
English, Chinese, Japanese
Platform:
Windows, Mac, Linux
Product Name:
Daoru
Product Type:
Software
Support:
Live Chat, Email, Phone
Highlight:

ground bond resistance tester

,

hipot ground continuity tester

,

hipot ground bond tester

Introduction

Daoru TH9410A 1.00-5.00A Ground Resistance Tester with 0-600m Range

  1. Voltage Output Range: Hipot Testers offer a wide range of voltage outputs to accommodate various testing requirements. The voltage output can typically be adjusted within a specified range, allowing the user to select the appropriate voltage level based on the insulation rating of the device or component under test.

Features

Test current: 1.00-32.00A

Grounding resistance range: 0-600m

Four-terminal test mode to ensure test accuracy

The internal power amplifier circuit drives the current output, which is not affected by the power supply and load

The output holes on the front and rear panels are designed to facilitate the integration of standard chassis

480×272 dots, TFT-LCD display

999.9 seconds test time, which is greater than common 60S test requirements

Keyboard lock function to prevent misoperation

Safety lock function to prevent the instrument from accidentally opening the test state

Store 20 test files, each with 20 test steps

Application

Automated test system

Household appliances

Transformer, motor

Electrical equipment

Electric heating appliances

Lighting industry

New energy vehicles

Electronic components

Medical equipment

Specifications

Model TH9410A TH9411A
Output Current Scop 1A-45A 1A-32A
Range 1.00A-5.00A 5.01A-30A 30.01A- 45A 1.00A-5.00A 5.01A-32A
Accuracy ±(2% Reading + 3 Digit)
Setting Resolution 0.01A
Readback Resolution 0.01A
Output Voltage 8Vmax 6Vmax 8Vmax
Frequency 50 / 60Hz0.1%SET
Resistance Test Range 0-600m (Rmax <=6 / Iset (Iset: Setting Current)), The max Resistance could be 600m when the current is less than 10A.
Accuracy ± (2% Reading + 2 Digit)
Resolution 1 m 0.1 m 0.1 m 1 m 0.1 m
Setting Upper Limit 0-600m
Lower Limit 0-600m (Less than Upper Limit)
Resolution 1m
Bias Range 0 - 100 m
Resolution 0.1m
Accuracy ± (2% Setting + 2 Digit)
Test Time Range 0, 0.5 - 999.9s (0 = Continuous)
Resolution 0.1s
Accuracy ± (0.1% + 0.05s)
Input Power Voltage 110V, 220V
Frequency 47.5-63Hz
Power Consumption <=900VA <= 800VA
Size 340mm×120mm×450mm 340mm×120mm×450mm
Weight About 15kg About 15kg

 

Accessary

Standard
Accessories name Model  
Optional
Accessories name Model  
Send RFQ
Stock:
MOQ: