Send Message
Home > products > Electronic Component Testers > 50hz-200khz Lcr Meter For Capacitance Measurement Lab 9 Levels Of Fine Range

50hz-200khz Lcr Meter For Capacitance Measurement Lab 9 Levels Of Fine Range

Category:
Electronic Component Testers
Specifications
Highlight:

200khz lcr meter

,

lcr meter measurement

,

lcr meter for capacitance measurement

Introduction

TH2816A+ Benchtop Type LCR Meter with 9 Levels of Fine Range for Lab Measurement

  1. High Measurement Speed: The LCR Meter is designed to deliver rapid measurement speeds, allowing for efficient testing and analysis. It can quickly measure and display results, reducing overall testing time and increasing productivity.

  2. Versatile Test Modes: The LCR Meter offers various test modes to accommodate different measurement requirements. It includes options such as series mode, parallel mode, and automatic mode, providing flexibility in measuring different types of components and circuits.

Brief Introduction

 

    TH2816P/TH2816A+/TH2816B+ precision LCR meter is the latest generation developed on the basis of TH2816A/B and TH2817A, which
are deeply trusted by customers. It integrates our company's many years of mature experience in component testing and uses the latest
technology in this fi eld.
     TH2816P improves the 0.05% accuracy of the original product to the 0.02% accuracy of the domestic ultra-high level, and at the same
time inherits and further improves the stability and consistency of the original product, making it one of the most advanced products in the
world. Combined with the low price, it will give our customers super value enjoyment.
   "TH2816P provides stable 7-bit test resolution, while TH2816A+/TH2816B+ continues to maintain 6-bit test resolution, and the basic frequency and
test level indicators are consistent with TH2816A/B and TH2817A series.The new-generation instrument prompts the test speed to the fastest about 60 times per second, provides 9 levels of fine range, constant 30Ω/100Ω source internal resistance and fl exible and humane operation mode, which
can meet the requirements of production line quality assurance, incoming inspection and laboratory high precision measurement requirements.
    The appearance of the new-generation instrument has been changed to the internationally popular black color, which is more beautiful
than the old model. At the same time, it has inherited all its operation function keys and menus, and old users can seamlessly upgrade.
    In addition to providing RS232C, HANDLER, and GPIB (option) interfaces like the old models, the new generation of instruments further provides
USB HOST and USB DEVICE interfaces. It provides more options for the instrument to be integrated in the automatic component sorting system,
communicate with the computer and record the test process data."

 

Application

 

• Passive components:
capacitors, inductors, magnetic cores, resistors, piezoelectric devices,transformers, chip components and Impedance parameter evaluation of network components, etc.
• Other components:
Impedance evaluation of PCB, relays, switches, cables, batteries, etc
 

  Feature

 

• 240×64 dot matrix graphic LCD display
• Humanized operation interface, easy to operate
• 0.02% accuracy (TH2816P), 7-digit reading 0.05% accuracy
(TH2816A+/TH2816B+) 6-digit reading
• 10mVrms - 2.0Vrms programmable test level
• Compatible with legacy bias source control
• High stability, high accuracy
• The fastest speed is about 60 times/second
• Accurate load calibration function
• 30Ω/100Ω selectable signal source output impedance
• 4-point frequency/level/list sweep function
• Direct reading, absolute deviation and relative deviation display
• 12 groups of internal instrument setting storage
• Built-in comparator:
10-bin sorting and bin counting (TH2816P/TH2816A+)
4 bins sorting and bin counting (TH2816B+)
• Test level monitoring function
• Keypad lock function

 

50hz-200khz Lcr Meter For Capacitance Measurement Lab 9 Levels Of Fine Range

 

Notable Features

 

A.Renewal and upgrade, all-round improvement

 

The appearance is upgraded from white to internationally popular black, which is more beautiful and refifined.

50hz-200khz Lcr Meter For Capacitance Measurement Lab 9 Levels Of Fine Range

In order to facilitate the operation of old users, the new generation of instruments retains the original instrument operation
mode, and the operation can be switched seamlessly

 
B.The measurement accuracy is upgraded to give customers a higher accuracy choice

The TH2816P test resolution is upgraded from 6 bits to 7 bits, and the measurement accuracy is upgraded from 0.05% to
0.02%.

50hz-200khz Lcr Meter For Capacitance Measurement Lab 9 Levels Of Fine Range

 

 

C.The measurement efficiency is upgraded, and the higher test speed improves the output rate of automation equipment

50hz-200khz Lcr Meter For Capacitance Measurement Lab 9 Levels Of Fine Range

Compared with the classic model TH2816A, the test speed of the new model has been greatly improved. In particular, the fast + mode has been added, and the test speed can reach 60 times per second (16.7ms), which fully doubles the efficiency of automated testing.

 

D.Stability and consistency are further improved
The following are the measurement results of 6 standard resistors in the range of 1Ω-100kΩ.
 

50hz-200khz Lcr Meter For Capacitance Measurement Lab 9 Levels Of Fine Range50hz-200khz Lcr Meter For Capacitance Measurement Lab 9 Levels Of Fine Range50hz-200khz Lcr Meter For Capacitance Measurement Lab 9 Levels Of Fine Range

E. Platform upgrade, more convenient maintenance
 
TH2816P/TH2816A+/TH2816B+ upgrades the original TH2816A series hardware platform. In addition to improving the
measurement accuracy, measurement speed, and measurement stability, it also upgrades the maintenance method.
When the instrument needs to correct the setting BUG, measure the BUG, or need to customize and modify the instrument
function, there is no need to return to the factory for upgrade, and it can be upgraded directly through the USB flflash drive, which
greatly saves feedback time.
Upgrade method: The upgrade fifile is imported into the USB flflash drive, inserted into the instrument, System-About
Update, and the upgrade can be completed in 10 seconds.
50hz-200khz Lcr Meter For Capacitance Measurement Lab 9 Levels Of Fine Range
Send RFQ
Stock:
MOQ: